6 resultados para quality measurement

em CORA - Cork Open Research Archive - University College Cork - Ireland


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The principal objective of this thesis was to investigate the ability of reversible optical O2 sensors to be incorporated into food/beverage packaging systems to continuously monitor O2 levels in a non-destructive manner immediately postpackaging and over time. Residual levels of O2 present in packs can negatively affect product quality and subsequently, product shelf-life, especially for O2-sensitive foods/beverages. Therefore, the ability of O2 sensors to continuously monitor O2 levels present within food/beverage packages was considered commercially relevant in terms of identifying the consequences of residual O2 on product safety and quality over time. Research commenced with the development of a novel range of O2 sensors based on phosphorescent platinum and palladium octaethylporphyrin-ketones (OEPk) in nano-porous high density polyethylene (HDPE), polypropylene (PP) polytetrafluoroethylene (PTFE) polymer supports. Sensors were calibrated over a temperature range of -10°C to +40°C and deemed suitable for food and beverage packaging applications. This sensor technology was used and demonstrated itself effective in determining failures in packaging containment. This was clearly demonstrated in the packaging of cheese string products. The sensor technology was also assessed across a wide range of packaged products; beer, ready-to-eat salad products, bread and convenience-style, muscle-based processed food products. The O2 sensor technology performed extremely well within all packaging systems. The sensor technology adequately detected O2 levels in; beer bottles prior to and following pasteurisation, modified atmosphere (MA) packs of ready-to-eat salad packs as respiration progressed during product storage and MA packs of bread and convenience-style muscle-based products as mycological growth occurred in food packs over time in the presence and absence of ethanol emitters. The use of the technology, in conjunction with standard food quality assessment techniques, showed remarkable usefulness in determining the impact of actual levels of O2 on specific quality attributes. The O2 sensing probe was modified, miniaturised and automated to screen for the determination of total aerobic viable counts (TVC) in several fish species samples. The test showed good correlation with conventional TVC test (ISO:4833:2003), analytical performance and ruggedness with respect to variation of key assay parameters (probe concentration and pipetting volume). Overall, the respirometric fish TVC test was simple to use, possessed a dynamic microbial range (104-107 cfu/g sample), had an accuracy of +/- one log(cfu/g sample) and was rapid. Its ability to assess highly perishable products such as fish for total microbial growth in <12 hr demonstrates commercial potential.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At a time when technological advances are providing new sensor capabilities, novel network capabilities, long-range communications technologies and data interpreting and delivery formats via the World Wide Web, we never before had such opportunities to sense and analyse the environment around us. However, the challenges exist. While measurement and detection of environmental pollutants can be successful under laboratory-controlled conditions, continuous in-situ monitoring remains one of the most challenging aspects of environmental sensing. This paper describes the development and test of a multi-sensor heterogeneous real-time water monitoring system. A multi-sensor system was deployed in the River Lee, County Cork, Ireland to monitor water quality parameters such as pH, temperature, conductivity, turbidity and dissolved oxygen. The R. Lee comprises of a tidal water system that provides an interesting test site to monitor. The multi-sensor system set-up is described and results of the sensor deployment and the various challenges are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditional motion capture techniques, for instance, those employing optical technology, have long been used in the area of rehabilitation, sports medicine and performance analysis, where accurately capturing bio-mechanical data is of crucial importance. However their size, cost, complexity and lack of portability mean that their use is often impractical. Low cost MEMS inertial sensors when combined and assembled into a Wireless Inertial Measurement Unit (WIMU) present a possible solution for low cost and highly portable motion capture. However due to the large variability inherent to MEMS sensors, such a system would need extensive characterization to calibrate each sensor and ensure good quality data capture. A completely calibrated WIMU system would allow for motion capture in a wider range of real-world, non-laboratory based applications. Calibration can be a complex task, particularly for newer, multi-sensing range capable inertial sensors. As such we present an automated system for quickly and easily calibrating inertial sensors in a packaged WIMU, demonstrating some of the improvements in accuracy attainable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wireless Inertial Measurement Units (WIMUs) combine motion sensing, processing & communications functionsin a single device. Data gathered using these sensors has the potential to be converted into high quality motion data. By outfitting a subject with multiple WIMUs full motion data can begathered. With a potential cost of ownership several orders of magnitude less than traditional camera based motion capture, WIMU systems have potential to be crucially important in supplementing or replacing traditional motion capture and opening up entirely new application areas and potential markets particularly in the rehabilitative, sports & at-home healthcarespaces. Currently WIMUs are underutilized in these areas. A major barrier to adoption is perceived complexity. Sample rates, sensor types & dynamic sensor ranges may need to be adjusted on multiple axes for each device depending on the scenario. As such we present an advanced WIMU in conjunction with a Smart WIMU system to simplify this aspect with 3 usage modes: Manual, Intelligent and Autonomous. Attendees will be able to compare the 3 different modes and see the effects of good andbad set-ups on the quality of data gathered in real time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To investigate the value of using PROMs as quality improvement tools. Methods: Two systematic reviews were undertaken. The first reviewed the quantitative literature on the impact of PROMs feedback and the second reviewed the qualitative literature on the use of PROMs in practice. These reviews informed the focus of the primary research. A cluster randomised controlled trial (PROFILE) examined the impact of providing peer benchmarked PROMs feedback to consultant orthopaedic surgeons on improving outcomes for hip replacement surgery. Qualitative interviews with surgeons in the intervention arm of the trial examined the view of and reactions to the feedback. Results: The quantitative review of 17 studies found weak evidence to suggest that providing PROMs feedback to professionals improves patient outcomes. The qualitative review of 16 studies identified the barriers and facilitators to the use of PROMs based on four themes: practical considerations, attitudes towards the data, methodological concerns and the impact of feedback on care. The PROFILE trial included 11 surgeons and 215 patients in the intervention arm, and 10 surgeons and 217 patients in the control arm. The trial found no significant difference in the Oxford Hip Score between the arms (-0.7, 95% CI -1.9-0.5, p=0.2). Interviews with surgeons revealed mixed opinions about the value of the PROMs feedback and the information did not promote explicit changes to their practice. Conclusion: It is important to use PROMs which have been validated for the specific purpose of performance measurement, consult with professionals when developing a PROMs feedback intervention, communicate with professionals about the objectives of the data collection, educate professionals on the properties and interpretation of the data, and support professionals in using the information to improve care. It is also imperative that the burden of data collection and dissemination of the information is minimised.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Food allergy (FA) is a heavy burden for patients and their families and can significantly reduce the quality of life (QoL) of both. To provide adequate support, qualitative and quantitative evaluation of the parents' QoL may be helpful. The objective of this study is to develop and validate a Japanese version of the Food Allergy QoL QuestionnaireeParent Form (FAQLQ-PF-J), an internationally validated disease-specific QoL measurement of the parental burden of having a child with FA. Methods: The FAQLQ-PF and the Food Allergy Independent Measure (FAIM), an instrument to test the construct validity of the FAQLQ-PF-J, were translated into Japanese. After language validation, the questionnaires were administered to parents of FA children aged 0e12 years and those of age-matched healthy (without FA) children. Internal consistency (by Cronbach's a) and test-retest reliability were evaluated. Construct validity and discriminant validity were also examined. Results: One hundred twenty-seven parents of children with FA and 48 parents of healthy children filled out the questionnaire. The FAQLQ-PF-J showed excellent internal consistency (Cronbach's a > 0.77) and test-retest reliability. Good construct validity was demonstrated by significant correlations between the FAQLQ-PF-J and FAIM-J scores. It discriminated parents of children with FA from those without. The scores were significantly higher (lower QoL) for parents of FA children with a history of anaphylaxis than those without, for those with >6 FA-related symptoms experienced than those with less FA-related symptoms. Conclusions: The FAQLQ-PF-J is a reliable and valid measure of the parental burden of FA in children.